|
|
|
The ACTIVA Family
|
ACTIVA,
The Art in ICP Spectrometer
Expand your capabilites and performance!
ACTIVA, built on A Platform for the Future™,
maintains the strengths of HORIBA Jobin Yvon ICP spectrometers
while incorporating advanced CCD technology, thus offering:
-
Ultra
low noise megapixel CCD tailored for spectroscopy,
coupled to the original HORIBA Jobin Yvon holographic
grating-based optics
-
Constant
high resolution across the full spectrum
-
Superior
vertical torch-based Total Plasma View
-
Unique
sheath gas for high solids applications
-
Low
argon consumption, less glass torch parts replacement,
quick-mount torch
As a consequence, expanding the range of applications
in correlation with the large analytical benefits:
-
Few
spectral interference, few matrix effects, few
memory effects allowing complex matrix, high dissolved
solids or organic sample analysis
-
Excellent
limits of quantification thanks to simultaneous
measurement of background
-
Perfect
reproducibility, facilitating multi-user operation
-
Unrivalled
performance for alkaline elements
-
Linear
concentration range over five decades
The ACTIVA offers the practical use of ICP-AES analysis
by first time operators or sophisticated users, through
easy operation steps, for all types of applications.
ACTIVA-M,
The Master in True Multi-Line Analysis
Become an expert in quantitative ICP analysis!
Building on the popular, state of the art ACTIVA spectrometer,
the ACTIVA-M combines superb instrument performance
with unique advanced software tools.
Overcoming the challenges of multi-line selection
and achieving high reliability of results, the ACTIVA-M
benefits from innovative and interactive assistance,
through:
-
A
new proprietary ICP-focussed Database featuring
not only wavelength but also ionization level,
line width, limit of detection and dynamic range
of each line, thus providing data that allows the
combination of single-element spectra to mimic
real-life samples
-
M.A.S.T.E.R.
(Multi-line Analysis Selection Tool for Enhanced
Reliability) which performs a multi-line selection
according to the concentration range of each element
and matrix influences
-
S.O.S.
(Statistical Outlier Survey) which evaluates the
line concentration results through ANOVA data processing
to detect outliers and to provide a single reliable
result for each element
The advanced instrument configuration makes this unique
assistance a reality:
-
Extended
spectral range from 120 to 800 nm
-
Few
matrix effects and high spectral selectivity which
allows a greater choice of suitable wavelengths
to be used for multi-line analysis
-
Linear
concentration range over five decades, avoiding
detector saturation and risk of curvature, thereby
improving the statistics of the results
Request
Information
|
|
|
|